Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 640-642, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Revenant, M. C.
Right arrow Articles by Monnet, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Revenant, M. C.
Right arrow Articles by Monnet, L.

Clinical Chemistry, Vol 31, 640-642, Copyright © 1985 by American Association for Clinical Chemistry

Determination of serum ferritin by a one-step immunoenzymoassay, and comparison of four liver-ferritin standards

MC Revenant, J Goudable, A Beaudonnet, A Mailliavin, J Pichot and L Monnet

We describe a one step "sandwich"-type immunoenzymoassay for ferritin in human serum. The solid-phase consists of glutaraldehyde-treated polypropylene tubes coated with rabbit antibody to human ferritin. Liver ferritin is the standard. Peroxidase-conjugated antiserum to ferritin and a sensitive chromogen, o-phenylenediamine, are used. The assay requires 90 min. The standard curve is linear up to 400 micrograms of ferritin per liter of serum. Within- and between-run CVs are less than 6% for low, high, and medium concentrations and are about 13.0% at the decision level for iron deficiency. Results by a two-step "sandwich" procedure (New England Immunology Associates kit) correlated well, r = 0.98. We assessed four liver ferritin standards from different manufacturers with the described method. The mean absorbance for the 40 micrograms/L ferritin standard was 1.5 for that from Diagnostics Biochem and National Institute for Biological Standards and Controls, 1.0 for that from Dako, and 0.4 for that from Sigma. Consequently, to standardize results, all liver ferritin standards should be calibrated vs the National Institute for Biological Standards and Controls reference standard.