Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 861-863, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ysewijn-Van Brussel, K. A.
Right arrow Articles by De Leenheer, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ysewijn-Van Brussel, K. A.
Right arrow Articles by De Leenheer, A. P.

Clinical Chemistry, Vol 31, 861-863, Copyright © 1985 by American Association for Clinical Chemistry

Development and evaluation of a radioimmunoassay for Arg8-vasopressin, after extraction with Sep-Pak C18

KA Ysewijn-Van Brussel and AP De Leenheer

We describe a specific double-antibody radioimmunoassay for measuring arginine vasopressin (AVP) in human plasma. Antisera of high avidity were obtained from rabbits that had been injected with AVP coupled to bovine thyroglobulin. The antibody reacts with both the tripeptide tail and the pentapeptide ring of the molecule, thereby eliminating cross reaction with oxytocin. Synthetic AVP was labeled with 125I by a modification of the Chloramine-T technique. The specific activity of the labeled hormone was 29 MBq/micrograms of AVP, as estimated by self- displacement analysis. The assay involves Sep-Pak C18 extraction of acidified (pH 4) plasma. Recovery of [3H]AVP added to plasma averaged 86.6 (SD 6.1)% (n = 14). Dilution curves for plasma showed linearity of response with concentration. The overall sensitivity was 0.3 ng/L when 2-mL plasma samples were extracted. The intra-assay CV was 7.8% at 4.8 ng/L (n = 12) and the interassay CV was 12.3% (n = 16) and 6.3% (n = 14) at 2.7 and 4.1 ng/L concentrations, respectively.


The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Y. Fujisawa, N. Mori, K. Yube, H. Miyanaka, A. Miyatake, and Y. Abe
Role of nitric oxide in regulation of renal sympathetic nerve activity during hemorrhage in conscious rats
Am J Physiol Heart Circ Physiol, July 1, 1999; 277(1): H8 - H14.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Kluge, S. Riedl, B. Erhart-Hofmann, J. Hartmann, and F. Waldhauser
Improved Extraction Procedure and RIA for Determination of Arginine8-Vasopressin in Plasma: Role of Premeasurement Sample Treatment and Reference Values in Children
Clin. Chem., January 1, 1999; 45(1): 98 - 103.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.