Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1227-1228, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sullivan, D. R.
Right arrow Articles by Katan, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sullivan, D. R.
Right arrow Articles by Katan, M. B.

Clinical Chemistry, Vol 31, 1227-1228, Copyright © 1985 by American Association for Clinical Chemistry

Determination of serum triglycerides by an accurate enzymatic method not affected by free glycerol

DR Sullivan, Z Kruijswijk, CE West, M Kohlmeier and MB Katan

In this automated single-run enzymatic procedure for specific determination of triglycerides in serum, free glycerol is removed from the reaction mixture by pre-incubation with glycerol phosphate oxidase and peroxidase. The subsequent addition of lipase and the chromogen, 4- aminoantipyrine, results in the formation of color proportional to the amount of triglycerides in serum. Standards containing triolein in aqueous detergent are used to calibrate the method. For serum pools from the Centers for Disease Control with target values of 0.74, 1.41, and 2.63 mmol/L, the method produced biases of +0.01, -0.05, and 0.00 mmol/L, respectively (mean: -0.01 mmol/L or -0.4%). The mean coefficient of variation was 1.4% within and 2.5% between days; the combined CV, 2.9%. Ninety 6-microL serum samples can be analyzed per hour. The method is more accurate and precise than one based on an NADH- coupled enzyme system with separate addition of lipase.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. M. Moreno-Navarrete, F. J. Ortega, J. Bassols, A. Castro, W. Ricart, and J. M. Fernandez-Real
Association of Circulating Lactoferrin Concentration and 2 Nonsynonymous LTF Gene Polymorphisms with Dyslipidemia in Men Depends on Glucose-Tolerance Status
Clin. Chem., February 1, 2008; 54(2): 301 - 309.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
T. Kazumi, A. Kawaguchi, K. Sakai, T. Hirano, and G. Yoshino
Young Men With High-Normal Blood Pressure Have Lower Serum Adiponectin, Smaller LDL Size, and Higher Elevated Heart Rate Than Those With Optimal Blood Pressure
Diabetes Care, June 1, 2002; 25(6): 971 - 976.
[Abstract] [Full Text] [PDF]


Home page
CLIN APPL THROMB HEMOSTHome page
H. Kagawa, S. Nomura, M. Nagahama, Y. Ozaki, and S. Fukuhara
Effect of Bezafibrate on Soluble Adhesion Molecules and Platelet Activation Markers in Patients With Connective Tissue Diseases and Secondary Hyperlipidemia
Clinical and Applied Thrombosis/Hemostasis, April 1, 2001; 7(2): 153 - 157.
[Abstract] [PDF]


Home page
J. Nutr.Home page
J. J. M. Castenmiller, C. E. West, J. P. H. Linssen, K. H. van het Hof, and A. G. J. Voragen
The Food Matrix of Spinach Is a Limiting Factor in Determining the Bioavailability of ß-Carotene and to a Lesser Extent of Lutein in Humans
J. Nutr., February 1, 1999; 129(2): 349 - 355.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.