Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1272-1277, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gault, M. H.
Right arrow Articles by Vasdev, S. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gault, M. H.
Right arrow Articles by Vasdev, S. C.

Clinical Chemistry, Vol 31, 1272-1277, Copyright © 1985 by American Association for Clinical Chemistry

Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin

MH Gault, L Longerich, M Dawe and SC Vasdev

This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and replicates of sera with values of 0.5 to 1 microgram/L were 4 to 6%. Fifty-nine sera from 50 patients receiving digoxin were so studied. All digoxin metabolites appear to cross react with antibody to digoxin to various degrees. The most polar metabolites were quantitatively the most important, their average cross reactivity being 33%. For eight patients the value for digoxin by the present method was less than 60% of the RIA value. Sera from nine patients not taking digoxin but with falsely high digoxin values were also studied by the present method. The digoxin peak was well resolved from those for (a) digoxin metabolites (except dihydrodigoxin), (b) digitalis-like factors in neonates and in patients with renal failure or combined hepatic and renal failure, and (c) two cross reacting drugs and their metabolites.