Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1283-1288, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mifflin, T. E.
Right arrow Articles by Bruns, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mifflin, T. E.
Right arrow Articles by Bruns, D. E.

Clinical Chemistry, Vol 31, 1283-1288, Copyright © 1985 by American Association for Clinical Chemistry

Rapid quantitative, specific measurement of pancreatic amylase in serum with use of a monoclonal antibody

TE Mifflin, DC Benjamin and DE Bruns

In this rapid quantitative assay for pancreatic alpha-amylase (EC 3.2.1.1) in serum, we precipitate salivary amylases by 10-min incubation with monoclonal anti-salivary amylase antibody immobilized on particles of polyvinylidene fluoride. We then centrifuge the serum mixture and measure the pancreatic amylase activity remaining in the supernate by a kinetic method. The assay requires 50 microL of serum and the standard curve is linear to at least 1300 U of pancreatic amylase per liter of serum. CVs were 1.3% within-run, 6-8% day-to-day. Apparent analytical recovery of pancreatic amylase activity added to serum was 101% +/- 2%. Addition of purified salivary amylase, 356 U/L, to sera gave a value for apparent pancreatic amylase of less than 4 U/L, or 1% of the added salivary amylase activity. This assay correlated well with an electrophoretic method (slope, 0.97-0.99; intercept, 0.5 to -4 U/L; correlation coefficient, 0.946-0.990; and standard error of the estimate 3-5 U/L). Estimated normal reference intervals with maltotetraose as substrate were: total amylase, 39-118 U/L; pancreatic amylase, 11-50 U/L; and salivary amylase, 18-79 U/L.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.