Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1500-1505, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, C. R.
Right arrow Articles by Burd, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, C. R.
Right arrow Articles by Burd, J. F.

Clinical Chemistry, Vol 31, 1500-1505, Copyright © 1985 by American Association for Clinical Chemistry

Simultaneous determination of total IgE and allergen-specific IgE in serum by the MAST chemiluminescent assay system

CR Brown, KW Higgins, K Frazer, LK Schoelz, JW Dyminski, VA Marinkovich, SP Miller and JF Burd

We have developed a chemiluminescent immunoenzymometric system. The first commercial application of this chemiluminescent assay (CLA) is the measurement of total IgE and allergen-specific IgE in human serum. The CLA system is a second-generation adaptation of the MAST RIA allergy profiling system. The MAST CLA system assay protocol consists of three steps: overnight incubation of serum, a 4-h incubation with enzyme-labeled antibody, and a 30-min chemiluminescent reaction, which produces a visible image (immunograph) on high-speed Polaroid instant film. The densities of the bands produced on the film are quantified with an inexpensive microprocessor-controlled infrared transmittance densitometer. The novel luminogenic substrates used yield a constant light output for over 2 h with an intensity at least 10-fold greater than that of commercial chemiluminescent reagents. The MAST CLA system exhibits sensitivity, specificity, and precision equal to that of the MAST RIA system (r = 0.96 for 40 serum samples analyzed with 25 allergens). As many as 35 different allergens per sample can be quantified in a single assay. The MAST CLA system requires no standard curve or volume-dependent pipetting steps, incorporates both positive and negative controls for each sample, and quantifies allergen-specific IgE at picomolar concentrations.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
N. Honda, U. Lindberg, P. Andersson, S. Hoffmann, and H. Takei
Simultaneous Multiple Immunoassays in a Compact Disc-Shaped Microfluidic Device Based on Centrifugal Force
Clin. Chem., October 1, 2005; 51(10): 1955 - 1961.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.