Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1557-1559, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rypins, E. B.
Right arrow Articles by Wynn, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rypins, E. B.
Right arrow Articles by Wynn, M. J.

Clinical Chemistry, Vol 31, 1557-1559, Copyright © 1985 by American Association for Clinical Chemistry

Bedside micro-method for measuring effective hepatic blood flow, with use of first-order galactose clearance pharmacokinetics

EB Rypins, H Sankary and MJ Wynn

Data from first-order galactose clearance were used to estimate "effective" hepatic blood flow in normal subjects and in patients with hepatic diseases. Galactose clearance was determined by infusing galactose intravenously at a constant rate and measuring its resulting steady-state concentration in blood. The infusion rate must not exceed the maximum rate of galactose clearance by the liver, the "galactose elimination capacity." With this constraint and within the physiological and pathophysiological limits of hepatic blood flow, a constant infusion at 50 mg/min results in steady-state concentrations ranging from 20 to 200 mg/L. To measure galactose within this range, we modified a YSI Model 23A glucose analyzer and, using an immobilized galactose oxidase (EC 1.1.3.9)/hydrogen peroxide electrode system, accurately measured galactose in water and blood. The galactose metabolic clearance rate was calculated for six normal rats and for a normal and a cirrhotic human subject. The speed of the analysis (40 s), the small sample required (25 microL), and the suitability of fresh whole blood as the sample make the method ideal for measuring hepatic blood flow in small laboratory animals as well as for determining at bedside the effective hepatic blood flow in humans.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.