Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 1873-1878, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Odell, W. D.
Right arrow Articles by Zahradnik, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Odell, W. D.
Right arrow Articles by Zahradnik, R.

Clinical Chemistry, Vol 32, 1873-1878, Copyright © 1986 by American Association for Clinical Chemistry

Two-monoclonal-antibody sandwich-type assay for thyrotropin, with use of an avidin-biotin separation technique

WD Odell, J Griffin and R Zahradnik

We have developed a sensitive, specific, noncompetitive, sandwich-type radioimmunoassay for human thyrotropin (hTSH), which can be performed in 30 min. The assay involves two monoclonal antibodies, selected for high affinity and specificity and also for reaction against antigenic sites on hTSH that are distal from each other. One of these antibodies is labeled with 125I; the other is conjugated covalently to biotin. Polystyrene beads were also conjugated covalently to biotin. After conjugation, the beads were incubated with avidin. These beads represent a rapid, simple method for separating hTSH-bound antibody from free antibody. The biotin-antibody-hTSH-125I-labeled antibody complexes bind to the beads and hTSH concentration is directly related to counts per minute. This assay can detect hTSH at a concentration of 0.06 milli-unit/L in serum.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. Deinum, F. H.M. Derkx, and M. A.D.H. Schalekamp
Improved Immunoradiometric Assay for Plasma Renin
Clin. Chem., June 1, 1999; 45(6): 847 - 854.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. H. J. Danser, C. A. M. van Kesteren, W. A. Bax, M. Tavenier, F. H. M. Derkx, P. R. Saxena, and M. A. D. H. Schalekamp
Prorenin, Renin, Angiotensinogen, and Angiotensin-Converting Enzyme in Normal and Failing Human Hearts : Evidence for Renin Binding
Circulation, July 1, 1997; 96(1): 220 - 226.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.