Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 1895-1900, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Boever, J.
Right arrow Articles by Vandewalle, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Boever, J.
Right arrow Articles by Vandewalle, L.

Clinical Chemistry, Vol 32, 1895-1900, Copyright © 1986 by American Association for Clinical Chemistry

Direct chemiluminescence immunoassay for estradiol in serum

J De Boever, F Kohen, C Usanachitt, D Vandekerckhove, D Leyseele and L Vandewalle

In this simple, reliable, fast solid-phase chemiluminescence immunoassay for directly measuring (i.e., without prior extraction) estradiol-17 beta in serum, a monoclonal antibody is used that binds estradiol with high affinity (Ka = 10(10) L/mol), and does not bind other steroids tested, the highest cross reactivity observed being 0.1% for estradiol-17 alpha. In this system the monoclonal antibody is bound to the wells of microtiter plates via a second antibody directed against the monoclonal antibody. Fifty microliters of serum and estradiol-displacing agents are added, followed by 100 pg of estradiol- isoluminol conjugate, and the label is measured by luminometry after the binding reaction. The sensitivity of the assay is 180 pmol per liter of serum, and the effective working range at less than or equal to 10% CV is 270 to 6700 pmol/L. Analytical recovery of added estradiol averaged 99.7% (SD 6.5%). Within- and between-assay CVs ranged between 5 and 12.7%. Thirty-five unknown serum samples can be assayed within 4 h. Results correlated well with those obtained with a direct RIA: r = 0.94 (n = 149). This assay opens new perspectives for chemiluminescence immunoassays.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
K. Tamate, M. Charleton, J. P. Gosling, D. Egan, M. Ishikawa, P. F. Fottrell, and M. M. Kane
Direct colorimetric monoclonal antibody enzyme immunoassay for estradiol-17{beta} in saliva
Clin. Chem., July 1, 1997; 43(7): 1159 - 1164.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.