Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 2056-2059, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haver, V. M.
Right arrow Articles by Tietz, N. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haver, V. M.
Right arrow Articles by Tietz, N. W.

Clinical Chemistry, Vol 32, 2056-2059, Copyright © 1986 by American Association for Clinical Chemistry

Clinical and laboratory evaluation of a radioimmunoassay kit for measuring the mid-molecule fraction of parathyrin

VM Haver, AD Rinker, BM Ko and NW Tietz

We report the results of a laboratory and clinical evaluation of a commercial kit procedure (Immuno Nuclear Corp.) for measuring the mid- region of the parathyrin molecule. The estimated dose at 50% binding averaged 130 pmol/L, and the minimum detectable concentration was 14 pmol/L. The within-assay CV was less than or equal to 6.6%, the between- assay CV less than or equal to 12.5%. Relative analytical recoveries of various parathyrin fragments averaged 93% (intact, amino acid residues 1-84), 100% (midregion, 44-68), less than 0.01% (N-terminal, 1-34), and less than 0.01% (C-terminal, 69-84). Correlation of results obtained for 59 patients' samples with a radioimmunoassay for midregion/C- terminal parathyrin performed by the Mayo Medical Laboratory yielded the equation INC = 1.16 (Mayo)-1.94 pmol/L (r = 0.971). Clinical evaluation indicates that the INC results for parathyrin correlate with the diagnoses of patients at least as well as the results obtained with the Mayo assay; in some cases, the INC procedure better distinguishes hyperfunction from normal parathyroid function. The INC procedure can be easily performed in hospital laboratories, with a 4-h turnaround time for results.