Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 2133-2136, 1986;
This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baker, J.
Right arrow Articles by Johnson, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, J.
Right arrow Articles by Johnson, R.

Clinical Chemistry, Vol 32, 2133-2136, Copyright © 1986 by American Association for Clinical Chemistry

Quality assessment of determinations of serum fructosamine in 33 clinical chemistry laboratories

J Baker, P Metcalf, M Tatnell, M Lever and R Johnson

We investigated the analytical performance of fructosamine measurement in 33 routine clinical chemistry laboratories. We prepared 12 human control sera spanning a range of nondiabetic and diabetic fructosamine concentrations and assigned target values by using commercial reagents and a Cobas Bio centrifugal analyzer. Each control serum was analyzed by participating laboratories on two separate occasions. Averaged results were compared with target values, and systematic error was determined from slope and intercept regression coefficients. Overall, we found no significant (p greater than 0.05) slope or intercept bias, although slight nonlinearity was found with bichromatic instruments. Random error was determined from the standard error of estimate and from duplicate measurements. We found a median interlaboratory CV of 5.36% and similar analytical performance with all automated instruments used. The median random error with manual techniques was 18.1%. We conclude that fructosamine measurement as currently performed in routine laboratories is sufficiently accurate and reliable to function as an index of blood glucose control in diabetic patients.