Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 356-357, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kahn, S. N.
Right arrow Articles by Strony, L. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kahn, S. N.
Right arrow Articles by Strony, L. P.

Clinical Chemistry, Vol 32, 356-357, Copyright © 1986 by American Association for Clinical Chemistry

Imprecision of quantification of serum protein fractions by electrophoresis on cellulose acetate

SN Kahn and LP Strony

We studied the precision of densitometric quantification of the protein zones resolved by cellulose acetate electrophoresis. Replicate analyses of patients' samples by a single technologist showed mean CVs ranging from 2.9% for serum albumin to 9.5% for alpha 1-globulin. There were marked differences in measurements obtained by replicate analysis of the same samples by two experienced technologists. We calculated what changes in fractional concentrations would be analytically significant and concluded that densitometry of cellulose acetate electrophoretograms can only be semi-quantitative. We suggest that visual interpretation of high-resolution electrophoretic patterns by a trained observer can replace densitometry in most cases.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M.-L. Chen and C.-W. Lam
Protein Zone Electrophoresis of Pleural Effusion: The Diagnostic Separation of Transudates and Exudates
Clin. Chem., October 1, 1999; 45(10): 1882 - 1885.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
X. Bossuyt, A. Bogaerts, G. Schiettekatte, and N. Blanckaert
Serum protein electrophoresis and immunofixation by a semiautomated electrophoresis system
Clin. Chem., May 1, 1998; 44(5): 944 - 949.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
X. Bossuyt, G. Schiettekatte, A. Bogaerts, and N. Blanckaert
Serum protein electrophoresis by CZE 2000 clinical capillary electrophoresis system
Clin. Chem., April 1, 1998; 44(4): 749 - 759.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Bienvenu, M. S. Graziani, F. Arpin, H. Bernon, C. Blessum, C. Marchetti, G. Righetti, M. Somenzini, G. Verga, and F. Aguzzi
Multicenter evaluation of the Paragon CZETM 2000 capillary zone electrophoresis system for serum protein electrophoresis and monoclonal component typing
Clin. Chem., March 1, 1998; 44(3): 599 - 605.
[Abstract] [Full Text] [PDF]


Home page
Arch DermatolHome page
J. H. Prystowsky, S. N. Kahn, and G. S. Lazarus
Present Status of Pyoderma Gangrenosum: Review of 21 Cases
Arch Dermatol, January 1, 1989; 125(1): 57 - 64.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.