Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 819-825, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Demacker, P. N.
Right arrow Articles by Baadenhuysen, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Demacker, P. N.
Right arrow Articles by Baadenhuysen, H.

Clinical Chemistry, Vol 32, 819-825, Copyright © 1986 by American Association for Clinical Chemistry

Evaluation of the dual-precipitation method for determination of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 in serum

PN Demacker, HL Hak-Lemmers, AG Hijmans and H Baadenhuysen

We compared the dual-precipitation method for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 (Gidez et al., J Lipid Res 1982;23:1206-33) with density-gradient ultracentrifugation in a swinging-bucket rotor (Demacker et al., Clin Chem 1983;29:656-63). The concentration of dextran sulfate 15,000 (DS) needed for optimal accuracy of the HDL2-chol and HDL3-chol values was established empirically. At a DS concentration of 0.87 g/L, the values for HDL2-chol as well as for HDL3-chol in 88 sera did not differ significantly from those obtained by ultracentrifugation. The precision of the method was satisfactory and was related to the concentration. Nevertheless, the dual-precipitation method lacks specificity inasmuch as it produces no fractions that contain only one HDL subfraction. HDL2 and HDL3 each contained an equivalent amount of cholesterol from the other. At increasing DS concentrations, some radiolabeled HDL3 appeared to have precipitated prior to complete precipitation of HDL2. This lack of specificity can be tolerated in large-scale epidemiological studies for screening, but not in small-scale intervention studies or in assay of clinical samples, where better accuracy is needed and ultracentrifugation is preferred.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Lipid Res.Home page
T. Hirano, K. Nohtomi, S. Koba, A. Muroi, and Y. Ito
A simple and precise method for measuring HDL-cholesterol subfractions by a single precipitation followed by homogenous HDL-cholesterol assay
J. Lipid Res., May 1, 2008; 49(5): 1130 - 1136.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.