Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 1311-1317, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Proelss, H. F.
Right arrow Articles by Townsend, T. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Proelss, H. F.
Right arrow Articles by Townsend, T. B.

Clinical Chemistry, Vol 32, 1311-1317, Copyright © 1986 by American Association for Clinical Chemistry

Simultaneous liquid-chromatographic determination of five antiarrhythmic drugs and their major active metabolites in serum

HF Proelss and TB Townsend

We report an isocratic "high-performance" liquid chromatographic method for the simultaneous measurement of tocainide, lidocaine, procainamide, quinidine, disopyramide, and their major active metabolites in serum. The drugs are extracted from 200 microL of serum at pH 9.5 with 1.5 mL of 1,2-dichloromethane, concentrated by evaporation, and separated on a CN-bonded-phase column at 40 degrees C (flow rate 2 mL/min) with a pH 7.1 mobile phase of acetonitrile/methanol/phosphate buffer (60/7/33, by vol); the phosphate buffer contains 10 mmol of KH2PO4 and 0.5 mmol of triethylamine per liter. The antiarrhythmic drugs elute in the K' (capacity factor) range of 1.43 (lidocaine) to 5.7 (disopyramide). Results vary linearly with drug concentration to at least 30 mg/L; the detection limit is 0.1-0.2 mg/L. Within-run precision (CV) ranges from 0.9% to 5.0% and day-to-day precision from 2.1% to 6.2%, depending on the specific drug and its concentration in serum. Extraction efficiencies vary from 76% to 85% and analytical recoveries from 98.5% to 103%. At toxic serum concentrations, several basic drugs may interfere with the assay of some antiarrhythmics, but only hydroxyzine, verapamil, and certain local anesthetics interfere at therapeutic concentrations.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.