Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 1537-1539, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sonnenblick, M.
Right arrow Articles by Hershko, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sonnenblick, M.
Right arrow Articles by Hershko, C.

Clinical Chemistry, Vol 32, 1537-1539, Copyright © 1986 by American Association for Clinical Chemistry

Paraprotein interference with colorimetry of phosphate in serum of some patients with multiple myeloma

M Sonnenblick, U Eylath, R Brisk, C Eldad and C Hershko

In untreated serum of three patients with multiple myeloma, concentrations of inorganic phosphate ranged from 130 to 270 mg/L as measured with a chromogenic assay based on the interaction of phosphate ion with ammonium molybdate in the presence of ferrous sulfate. There were no clinical features of hyperphosphatemia, and values for total calcium concentration in serum remained within normal limits throughout. Subsequent investigations demonstrated that this hyperphosphatemia was spurious and was caused by high concentrations of the paraprotein interfering with the chromogenic assay. Because this type of assay, adapted for automated systems, is now widely used in clinical laboratories, we call attention to this limitation to avoid confusion in clinical evaluations of patients with multiple myeloma.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. Nauti, A. Barassi, G. Merlini, and G. V. M. d'Eril
Paraprotein Interference in an Assay of Conjugated Bilirubin
Clin. Chem., June 1, 2005; 51(6): 1076 - 1077.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Smogorzewska, J. G. Flood, W. H. Long, and A. S. Dighe
Paraprotein Interference in Automated Chemistry Analyzers
Clin. Chem., September 1, 2004; 50(9): 1691 - 1693.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Association for Clinical Chemistry.