Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 32: 1672-1676, 1986;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Castellani, W. J.
Right arrow Articles by Chou, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Castellani, W. J.
Right arrow Articles by Chou, D.

Clinical Chemistry, Vol 32, 1672-1676, Copyright © 1986 by American Association for Clinical Chemistry

Robotic sample preparation evaluated for the immunochemical determination of cardiac isoenzymes

WJ Castellani, F Van Lente and D Chou

A general-purpose bench-top laboratory robot was programmed to perform sample preparation for immunoprecipitative and immunoinhibitory determinations of cardiac isoenzymes with commercial kits. Run size could be varied from 1 to 24 patients' samples, and was determined by the robot without prompting. The robot placed the processed samples into a sample rotor for dried transfer to a batch centrifugal analyzer. Robotic precision compared well with that of manual performance of the same procedures at four concentrations of lactate dehydrogenase (EC 1.1.1.27) isoenzyme 1 activity and at one of two concentrations of creatine kinase (EC 2.7.3.2.) isoenzyme MB activity; for the other creatine kinase MB concentration, use of the robot significantly improved precision. Results for 100 samples from patients after open- heart surgery were highly correlated with manually obtained results for both isoenzyme determinations (r less that 0.96 each). Time to completion for small run sizes for either approach was comparable about 25 min. For larger batches, robotic run time increased rapidly, to 169 min for 24 patients' samples vs 41 min by manual assay.