Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 48-51, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bador, R.
Right arrow Articles by Desuzinges, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bador, R.
Right arrow Articles by Desuzinges, C.

Clinical Chemistry, Vol 33, 48-51, Copyright © 1987 by American Association for Clinical Chemistry

Europium and samarium as labels in time-resolved immunofluorometric assay of follitropin

R Bador, H Dechaud, F Claustrat and C Desuzinges

This time-resolved immunofluorometric assay for human follitropin involves use of europium- or samarium-labeled monoclonal antibodies, with an average incorporation ratio of 3 mol of Eu3+ or Sm3+ per mole of antibody. These lanthanide ions are bound to the antibody molecules by means of the anhydride of diethylenetriaminepentaacetic acid. The solid-phase antibody is immobilized inside polystyrene tubes in which plasma samples were assayed in a one-step procedure. After incubation, the fluorescence intensity of Eu3+ or Sm3+ label is measured by time- resolved fluorometry, with a nitrogen laser as the pulsed excitation source. The sensitivity of the assay is largely better with Eu3+ than with Sm3+ because of the difference in their intrinsic luminescence properties. Results obtained with the proposed methods correlated well with those by an immunoradiometric method.


The following articles in journals at HighWire Press have cited this article:


Home page
Biol. Reprod.Home page
M. Jimenez, J.A. Spaliviero, A.J. Grootenhuis, J. Verhagen, C.M. Allan, and D.J. Handelsman
Validation of an Ultrasensitive and Specific Immunofluorometric Assay for Mouse Follicle-Stimulating Hormone
Biol Reprod, January 1, 2005; 72(1): 78 - 85.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Sjoroos, J. Ilonen, and T. Lovgren
Solid-Phase PCR with Hybridization and Time-resolved Fluorometry for Detection of HLA-B27
Clin. Chem., March 1, 2001; 47(3): 498 - 504.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Association for Clinical Chemistry.