Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 62-66, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Werner, E. R.
Right arrow Articles by Wachter, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Werner, E. R.
Right arrow Articles by Wachter, H.

Clinical Chemistry, Vol 33, 62-66, Copyright © 1987 by American Association for Clinical Chemistry

Determination of neopterin in serum and urine

ER Werner, A Bichler, G Daxenbichler, D Fuchs, LC Fuith, A Hausen, H Hetzel, G Reibnegger and H Wachter

Concentrations of neopterin, a product of activated macrophages, in serum from 662 apparently healthy individuals (ages 1 to 97 years, median 22 years) were measured by radioimmunoassay and the results statistically analyzed. Consistent with prior investigations on the urinary excretion of neopterin, we found no significant sex dependence, but values for subjects younger than 18 or older than 75 years were significantly higher. Renal clearance of neopterin in nine healthy individuals was 218 (SD 44) mL/min, which suggests that the kidneys have an active role in neopterin excretion. Results for neopterin concentrations measured in serum by RIA and "high-performance" liquid chromatography (HPLC) are consistent, but for urinary neopterin the concordance between methods was weak. Therefore, the RIA should be used only for measuring neopterin in serum. In comparison of the clinical utility of serum neopterin and urinary neopterin/creatinine concentrations, in patients with gynecological tumors, the latter values (measured by HPLC) discriminated slightly better between patients with favorable and unfavorable prognoses.


The following articles in journals at HighWire Press have cited this article:


Home page
CVIHome page
R. Sghiri, J. Feinberg, F. Thabet, K. Dellagi, J. Boukadida, A. Ben Abdelaziz, J. L. Casanova, and M. R. Barbouche
Gamma Interferon Is Dispensable for Neopterin Production In Vivo
Clin. Vaccine Immunol., December 1, 2005; 12(12): 1437 - 1441.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Rej
Clinical Chemistry through Clinical Chemistry: A Journal Timeline
Clin. Chem., December 1, 2004; 50(12): 2415 - 2458.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
X. Garcia-Moll, F. Coccolo, D. Cole, and J. C. Kaski
Serum neopterin and complex stenosis morphology in patients with unstable angina
J. Am. Coll. Cardiol., March 15, 2000; 35(4): 956 - 962.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
X Garcia-Moll, D Cole, E Zouridakis, and J C Kaski
Increased serum neopterin: a marker of coronary artery disease activity in women
Heart, March 1, 2000; 83(3): 346 - 350.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Association for Clinical Chemistry.