Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 1814-1816, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by el-Yazigi, A.
Right arrow Articles by Al-Humaidan, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by el-Yazigi, A.
Right arrow Articles by Al-Humaidan, A.

Clinical Chemistry, Vol 33, 1814-1816, Copyright © 1987 by American Association for Clinical Chemistry

Direct, simultaneous measurement of chloramphenicol and its monosuccinate ester in micro-samples of plasma by radial-compression liquid chromatography

A el-Yazigi, A Yusuf and A Al-Humaidan
Department of Biological and Medical Research, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.

A simple method of simultaneous analysis for chloramphenicol and chloramphenicol succinate in 10-microL samples of plasma is described. We injected the plasma samples directly into a radial-compression liquid chromatograph equipped with a precolumn module and a C18 insert. A mixture of acetic acid solution (pH 3)/acetonitrile (75/25, by vol) was used as mobile phase, at a flow rate of 4 mL/min. We separated the compounds in a 10-micron (particle size) C18 cartridge with a radial compression separation system and detected them in the effluent at 280 nm. The peak height for both compounds was linearly (r greater than 0.9993) related to concentration over the range investigated, 1-50 mg/L. We also performed the analysis with use of an internal standard (methylprednisolone) and obtained equally good results (r greater than 0.9995). We observed no interference from other antibiotics or drugs in the assay, and the inter- and intra-run precision at different concentrations was good (CV, 0 to 5.6%). We analyzed microsamples of plasma from an infant treated for meningitis with chloramphenicol sodium succinate intravenously. Total analysis time for each sample was less than 8 min.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Association for Clinical Chemistry.