Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 1841-1850, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lensmeyer, G. L.
Right arrow Articles by Carlson, I. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lensmeyer, G. L.
Right arrow Articles by Carlson, I. H.

Clinical Chemistry, Vol 33, 1841-1850, Copyright © 1987 by American Association for Clinical Chemistry

Identification and analysis of nine metabolites of cyclosporine in whole blood by liquid chromatography. 1: Purification of analytical standards and optimization of the assay

GL Lensmeyer, DA Wiebe and IH Carlson
Department of Pathology and Laboratory Medicine, University of Wisconsin, Madison 53792.

We describe an extraction and an isocratic "high-performance" liquid- chromatographic (HPLC) separation of cyclosporine (CsA) and nine metabolites (M1, M8, M17, M18, M21, M25, M26, M203-218, and MUNDF1) from whole blood. Metabolites (for standards) were purified from human bile with liquid-liquid and solid-phase extractions, chromatographed on a cyanopropyl (CN) semipreparative HPLC column, and further purified on octyl, CN, and silica columns. The identity of each metabolite was verified with authentic standards on three chemically different HPLC columns and on the basis of cross-reactivity data from radioimmunoassay. For the routine analytical method, 1 mL of whole blood is diluted, hemolyzed, and applied to a Bond Elut CN (500 mg) cartridge to extract CsA, metabolites, and cyclosporin C, the internal standard. Interferences are removed by using four wash solutions and an additional cartridge of octyldecyl sorbent introduced prior to elution. Analytes are separated on a Zorbax CN analytical column maintained at 58 degrees C, with detection at 214 nm. Analytical recovery, as tested with three lots of CN sorbent, ranged from 47% to 95% for the 10 cyclosporines. Between-run CVs are less than 10% at 200 micrograms/L (concentration of each compound) and the standard curves are linear to 1500 micrograms/L. We also report a study of the separation mechanisms.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. R. Terrell, T. M. Daly, K. G. Hock, D. C. Kilgore, T. Q. Wei, S. Hernandez, D. Weibe, L. Fields, L. M. Shaw, and M. G. Scott
Evaluation of a No-Pretreatment Cyclosporin A Assay on the Dade Behring Dimension RxL Clinical Chemistry Analyzer
Clin. Chem., July 1, 2002; 48(7): 1059 - 1065.
[Abstract] [Full Text] [PDF]