Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 1978-1982, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schiele, F.
Right arrow Articles by Siest, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schiele, F.
Right arrow Articles by Siest, G.

Clinical Chemistry, Vol 33, 1978-1982, Copyright © 1987 by American Association for Clinical Chemistry

Production and certification of an enzyme reference material for gamma- glutamyltransferase (CRM 319). Part 2: Certification campaign

F Schiele, J Muller, E Colinet and G Siest
Centre de Medecine Preventive, Vandoeuvre-les-Nancy, France.

We describe the process of certification for a gamma- glutamyltransferase reference material (CRM no. 319). Fifteen laboratories participated to this interlaboratory evaluation. All steps of the measurements were controlled in an effort to locate potential sources of variations. In particular, the exclusion of some data was strictly documented or justified by the non-observance of the IFCC method and (or) discrepancies in instrumentation, reconstitution of the lyophilized samples, or measurement technique. Inaccuracy in the reconstitution of the lyophilized material was +/- 0.68%, and the molar absorptivity of the 5-amino-2-nitrobenzoate reported by each laboratory was within +/- 2% limits of the value reported by the IFCC. Calculated from the sets of accepted results, the total CV among samples was 2.6% and the overall CV was 3.2%. Within-day and between-day CVs were 1.1% and 1.4%, respectively. The greatest variation for a single component was the between-laboratory variability (CV 3.1%); the within-laboratory CV, including the day effect, was 1.8%. Finally, the certified value for the catalytic concentration of this enzyme in the reconstituted lyophilized reference material was 86.8 U/L with an uncertainty of +/- 2.1 U/L (0.95 confidence interval). The uncertainty appeared to be compatible with the end-use of this reference material.