Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 1994-1999, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Khosravi, M. J.
Right arrow Articles by Diamandis, E. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Khosravi, M. J.
Right arrow Articles by Diamandis, E. P.

Clinical Chemistry, Vol 33, 1994-1999, Copyright © 1987 by American Association for Clinical Chemistry

Immunofluorometry of choriogonadotropin by time-resolved fluorescence spectroscopy, with a new europium chelate as label

MJ Khosravi and EP Diamandis
CyberFluor Inc., Toronto, Canada.

We describe a new "sandwich"-type non-isotopic immunoassay for human choriogonadotropin (hCG) in serum. In the assay, hCG is captured by a beta-subunit-specific monoclonal antibody, which is immobilized in a white microtiter well. The sandwich is completed by adding a second biotinylated monoclonal antibody specific for the whole hCG molecule. The degree of binding of biotinylated antibody, which is proportional to the amount of hCG present in the sample, is quantified by adding streptavidin labeled with the europium chelate 4,7- bis(chlorosulfophenyl)-1,10-phenanthroline-2,9-dicarboxylic acid (BCPDA), in the presence of excess Eu3+. The fluorescent complex formed on the solid-phase [monoclonal antibody-hCG-monoclonal antibody-biotin- streptavidin-BCPDA-Eu3+] is measured by excitation at 337.1 nm with a nitrogen laser and monitoring the emission at 615 nm in a specially designed gated fluorometer working in a time-resolved mode. A two-step procedure is proposed for routine use to avoid the "high-dose hook effect" of the simpler and faster one-step procedure. The hCG assay described has a dynamic range of 1 to 500 int. units/L, and is precise and accurate. Results agree well with those obtained with a commercially available immunoradiometric and a time-resolved immunofluorometric procedure.


The following articles in journals at HighWire Press have cited this article:


Home page
Biol. Reprod.Home page
J.I.J. van Casteren, W.G.E.J. Schoonen, and H.J. Kloosterboer
Development of Time-Resolved Immunofluorometric Assays for Rat Follicle-Stimulating Hormone and Luteinizing Hormone and Application on Sera of Cycling Rats
Biol Reprod, April 1, 2000; 62(4): 886 - 894.
[Abstract] [Full Text]


Home page
J. Clin. Endocrinol. Metab.Home page
J. Khosravi, A. Diamandi, J. Mistry, and R. G. Krishna
The High Molecular Weight Insulin-Like Growth Factor-Binding Protein Complex: Epitope Mapping, Immunoassay, and Preliminary Clinical Evaluation
J. Clin. Endocrinol. Metab., August 1, 1999; 84(8): 2826 - 2833.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
M. J. Khosravi, A. Diamandi, and J. Mistry
Immunoassay of insulin-like growth factor binding protein-1
Clin. Chem., March 1, 1997; 43(3): 523 - 532.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Association for Clinical Chemistry.