Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 2191-2194, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boerman, O. C.
Right arrow Articles by Poels, L. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boerman, O. C.
Right arrow Articles by Poels, L. G.

Clinical Chemistry, Vol 33, 2191-2194, Copyright © 1987 by American Association for Clinical Chemistry

Time-resolved immunofluorometric assay for the ovarian carcinoma- associated antigenic determinant CA 125 in serum

OC Boerman, CM Thomas, MF Segers, P Kenemans, T Lovgren, VR Zurawski, HJ Haisma and LG Poels
Department of Cytology & Histology, Medical Faculty, Catholic University Nijmegen, The Netherlands.

A time-resolved immunofluorometric assay (IFMA) is described for quantifying the ovarian carcinoma-associated antigenic determinant CA 125 in human serum. Monoclonal antibody to CA 125 is immobilized onto a microtiter well, and the same antibody labeled with a europium chelate is used as a tracer. After the immunoreaction the bound portion of the labeled antibody is quantified by dissociating the Eu3+ in a fluorescence-enhancement solution and measuring its fluorescence with a time-resolved fluorometer. The detection limit of the IFMA is 1.5 arb. units/mL, being about the same as that of a commercially available immunoradiometric assay (IRMA) for CA 125 (1.4 arb. units/mL). The analytical range of the IFMA extends to 2000 arb. units/mL, whereas the range of the IRMA is 500 arb. units/mL. For 29 serum samples from ovarian-cancer patients measured simultaneously in the IFMA and IRMA, orthogonal regression analysis gave the equation CA 125 (IFMA) = 0.9937 CA 125 (IRMA) - 1.211 arb. units/mL (Syx = 6.8681, r = 0.9932). Apparently, the IFMA for CA 125 is a convenient alternative to the IRMA for CA 125 because of short counting times, the use of nonradioactive, stable reagents, and the much-extended measuring range. Additionally, the microtiter format should lend itself to more fully automated procedures in laboratories doing many such analyses.