Clinical Chemistry, Vol 33, 300-302, Copyright © 1987 by American Association for Clinical Chemistry
EH Slaats, JC Kennedy and H Kruijswijk
We evaluated a "no-extraction" assay system for serum testosterone [Diagnostic Products "Coat-A-Count" testosterone (direct)] with respect to the influence of sex-hormone binding globulin (SHBG). We conclude that the SHBG concentration strongly affects this estimation. The quantity of testosterone measured in the presence of 90 nmol of SHBG per liter (the upper reference limit of SHBG for women) was only about 40% of that measured at the lower limit of the SHBG reference interval (30 nmol/L). For SHBG concentrations less than 30 nmol/L one can expect the testosterone concentrations measured to be relatively too high.
The following articles in journals at HighWire Press have cited this article:
![]() |
K. S. Fritz, A. J.S. McKean, J. C. Nelson, and R. B. Wilcox Analog-Based Free Testosterone Test Results Linked to Total Testosterone Concentrations, Not Free Testosterone Concentrations Clin. Chem., March 1, 2008; 54(3): 512 - 516. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Ankarberg-Lindgren and E. Norjavaara A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17 -estradiol in prepubertal children Eur. J. Endocrinol., January 1, 2008; 158(1): 117 - 124. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Kushnir, A. L. Rockwood, W. L. Roberts, E. G. Pattison, A. M. Bunker, R. L. Fitzgerald, and A. W. Meikle Performance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone Clin. Chem., January 1, 2006; 52(1): 120 - 128. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Taieb, B. Mathian, F. Millot, M.-C. Patricot, E. Mathieu, N. Queyrel, I. Lacroix, C. Somma-Delpero, and P. Boudou Testosterone Measured by 10 Immunoassays and by Isotope-Dilution Gas Chromatography-Mass Spectrometry in Sera from 116 Men, Women, and Children Clin. Chem., August 1, 2003; 49(8): 1381 - 1395. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Rinaldi, H. Dechaud, C. Biessy, V. Morin-Raverot, P. Toniolo, A. Zeleniuch-Jacquotte, A. Akhmedkhanov, R. E. Shore, G. Secreto, A. Ciampi, et al. Reliability and Validity of Commercially Available, Direct Radioimmunoassays for Measurement of Blood Androgens and Estrogens in Postmenopausal Women Cancer Epidemiol. Biomarkers Prev., July 1, 2001; 10(7): 757 - 765. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Winters, D. E. Kelley, and B. Goodpaster The analog free testosterone assay: are the results in men clinically useful? Clin. Chem., October 1, 1998; 44(10): 2178 - 2182. [Abstract] [Full Text] [PDF] |
||||