Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 1170-1176, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bookbinder, M. J.
Right arrow Articles by Panosian, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bookbinder, M. J.
Right arrow Articles by Panosian, K. J.

Clinical Chemistry, Vol 33, 1170-1176, Copyright © 1987 by American Association for Clinical Chemistry

Using the coefficient of correlation in method-comparison studies

MJ Bookbinder and KJ Panosian

The coefficient of correlation (R) is one of the most commonly computed statistics in method-comparison studies. Usually, it is simply quoted without interpretation. In this paper, we show how R may be used to detect interference, nonlinearity, and misuse of the imprecision components. Specifically, one may precisely predict what R should be by considering the imprecisions of the two methods being compared, even before the comparison is performed. When the actual R disagrees with the predicted R, then one of the mentioned effects is present. We also describe a statistical test to detect these effects at the P = 0.05 level, then evaluate this test by using computer simulation and present two examples of its use. We also present the theory underlying the usage of R, including how R is affected by the distribution and range of the data, by the joint imprecisions of the methods being compared, by the sample size, and by the randomness of the specimen-selection process.


The following articles in journals at HighWire Press have cited this article:


Home page
Eur Heart JHome page
N.G Bellenger, M.I Burgess, S.G Ray, A Lahiri, A.J.S Coats, J.G.F Cleland, and D.J Pennell
Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance. Are they interchangeable?
Eur. Heart J., August 2, 2000; 21(16): 1387 - 1396.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Association for Clinical Chemistry.