Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 33: 1579-1584, 1987;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ullman, E. F.
Right arrow Articles by Gibbons, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ullman, E. F.
Right arrow Articles by Gibbons, I.

Clinical Chemistry, Vol 33, 1579-1584, Copyright © 1987 by American Association for Clinical Chemistry

Use of liposome encapsulation in a combined single-liquid reagent for homogeneous enzyme immunoassay

EF Ullman, T Tarnowski, P Felgner and I Gibbons

A technique has been developed to permit mutually reactive macromolecular reagents used in immunoassays to be combined without premature reaction. A conjugate of glucose-6-phosphate dehydrogenase (EC 1.1.1.49) and theophylline has been encapsulated in 0.2-micron- diameter bi-lamellar liposomes. Suspensions of these liposomes had excellent stability. Whereas the enzyme activity of the free conjugate is rapidly inhibited by anti-theophylline antibody, a suspension of the encapsulated conjugate in a solution of the antibody and NAD+ (6.0 mmol/L) retained greater than 92% of the initial enzyme activity after standing for one year at 4 degrees C. At higher NAD+ concentrations the liposomes aggregated, and enzyme activity was inhibited by leakage of the NAD+ hydrolysis product, adenosine diphosphoryl 5-ribose (ADP- ribose), into the liposomes. Inhibition by ADP-ribose could be blocked and partly reversed by adding semicarbazide. The liposomes were efficiently lysed by Triton X-100, deoxycholate, or octyl glucoside, the kinetics and extent of lysis being affected by liposome size and correlating with the acid strength of various cholate derivatives. Addition of a serum sample and a solution of buffer, substrate, and detergent to a single reagent containing the liposomes and anti- theophylline antibody provided assay results equivalent to those obtained by conventional two-reagent EMIT homogeneous enzyme immunoassay for theophylline.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Association for Clinical Chemistry.