Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 113-117, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, H. D.
Right arrow Articles by Keller, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, H. D.
Right arrow Articles by Keller, H.

Clinical Chemistry, Vol 34, 113-117, Copyright © 1988 by American Association for Clinical Chemistry

One-point recalibration of heterogeneous enzyme immunoassays with non- linear calibration curves

HD Meyer and H Keller
Diagnostica Evaluation, Boehringer Mannheim GmbH, F.R.G.

We have investigated one-point recalibration of heterogeneous enzyme immunoassays involving nonlinear calibration curves. By using a factor determined from a single standard we updated calibration curves obtained earlier by means of multiple-point determination. The prerequisite for this method is a reproducible working procedure, i.e., as ensured by a fully mechanized system. In our investigations with Enzymun-Test system ES 600 (Boehringer Mannheim) we determined alpha 1- fetoprotein, carcinoembryonic antigen, digoxin, ferritin, thyroxin- binding globulin, triiodothyronine, and thyroxin in human serum pools over a period of two weeks with both full calibration and one-point recalibration. Comparisons of the results thereby obtained show that the means of the concentrations and the CVs for the alternative calibration procedures differed negligibly, even if we used reagents exposed to different temperatures for different periods of time. With the one-point recalibration procedure presented here, therefore, one can considerably reduce the time and effort spent on calibration.