Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 67-70, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vink, K. L.
Right arrow Articles by van Gansewinkel, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vink, K. L.
Right arrow Articles by van Gansewinkel, R.

Clinical Chemistry, Vol 34, 67-70, Copyright © 1988 by American Association for Clinical Chemistry

Direct spectrophotometry of bilirubin in serum of the newborn, with use of caffeine reagent

KL Vink, W Schuurman and R van Gansewinkel
Department of Clinical Chemistry, St. Joseph Ziekenhuis, Eindhoven, The Netherlands.

We recently described a direct spectrophotometric method for unconjugated bilirubin, with caffeine reagent (Clin Chem 1986;32:1389- 93). Because this method is independent of the protein matrix we used it for the preparation of bilirubin standards (Clin Chem 1987;33:1817- 21). Now, in this paper, we utilize the caffeine reagent in setting up a bilirubin method for serum from neonates. This resulted in a two- wavelength (465 and 528 nm) equation, which fully corrects for HbO2 interferences. In combination with a bilirubin standard, this equation may be transformed into a simple relative formula for use with this simple dilution method. We studied this two-wavelength method with 55 neonates' sera, comparing results with those by both the diazo method of Doumas et al. (Clin Chem 1985;31:1779-89) and the borate method of Hertz et al. (Scand J Clin Lab Invest 1974;33:215-30). We found that this new method is independent of hemolysis and of the matrix of the sera. Therefore, it is very suitable for use in neonatology.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. C. Kazmierczak, A. F. Robertson, P. G. Catrou, K. P. Briley, B. L. Kreamer, and G. R. Gourley
Direct Spectrophotometric Method for Measurement of Bilirubin in Newborns: Comparison with HPLC and an Automated Diazo Method
Clin. Chem., July 1, 2002; 48(7): 1096 - 1097.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.