Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2205-2207, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shrivastav, T. G.
Right arrow Articles by Kumari, G. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shrivastav, T. G.
Right arrow Articles by Kumari, G. L.

Clinical Chemistry, Vol 34, 2205-2207, Copyright © 1988 by American Association for Clinical Chemistry

Enzyme immunosorbent assay of prolactin with penicillinase as label

TG Shrivastav, PK Pandey and GL Kumari
Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, New Delhi, India.

This competitive, rapid, and sensitive enzyme immunosorbent assay for measuring human prolactin in plasma involves penicillinase (EC 3.5.2.6) as label. Microtiter plate wells coated with goat anti-rabbit gamma globulin are filled with antibody to prolactin and plasma sample or reference prolactin and incubated with penicillinase-labeled prolactin for 1 h at 37 degrees C. The enzyme activity of the bound complex is then measured. The assay is as sensitive as radioimmunoassay, the detection limit being 2.5 ng of prolactin per milliliter of plasma. The plasma prolactin values obtained by enzyme immunoassay correlated well with those determined by radioimmunoassay: r = 0.98, slope = 1.00, intercept = 1.11 ng/mL (n = 53).


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. Basu, T. G. Shrivastav, and K. P. Kariya
Preparation of Enzyme Conjugate through Adipic Acid Dihydrazide as Linker and Its Use in Immunoassays
Clin. Chem., August 1, 2003; 49(8): 1410 - 1412.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.