Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2211-2216, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Longerich, L.
Right arrow Articles by Gault, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Longerich, L.
Right arrow Articles by Gault, M. H.

Clinical Chemistry, Vol 34, 2211-2216, Copyright © 1988 by American Association for Clinical Chemistry

Disposable-column radioimmunoassay for serum digoxin with less interference from metabolites and endogenous digitalis-like factors

L Longerich, S Vasdev, E Johnson and MH Gault
General Hospital, St. John's, NF, Canada.

A preparative extraction step using disposable C18 low-pressure chromatography columns greatly improved the specificity of a commercially prepared digoxin radioimmunoassay (RIA). Elution solvents were isopropanol/water (15/85 by vol), which extracted most immunoreactive digitalis-like factors and metabolites, and methanol, which extracted digoxin for RIA. Many different digoxin RIA kits could be used. The coefficients of variation for replicates and duplicates were 4.6% and 5.2%. Analytical recoveries of digoxin standards in serum of 1.0, 0.5, and 0.1 microgram/L were 96%, 95%, and 88%, respectively. Serum digoxin was assayed by this method in 200 patients, 47 of whom were studied by HPLC-RIA. Values correlated better with "true digoxin" by HPLC-RIA (r = 0.93) than did values found by direct assay (r = 0.63). The mean for the isopropanol fraction as a percentage of the mean direct RIA value was higher for the 21 dialysis-dependent patients than was that found for the 179 nondialysis patients (P less than 0.004). The method is suggested as being most useful when metabolites or digitalis-like factors are known to be often high and values for digoxin are disproportionate to the dose.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.