Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 2556-2560, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bounaud, J. Y.
Right arrow Articles by Begon, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bounaud, J. Y.
Right arrow Articles by Begon, F.

Clinical Chemistry, Vol 34, 2556-2560, Copyright © 1988 by American Association for Clinical Chemistry

One-step chemiluminescent immunoassay of free thyroxin with acridinium- ester-labeled thyroxin evaluated and compared with a two-step radioimmunoassay

JY Bounaud, MP Bounaud and F Begon
Service de Medecine Nucleaire et de Biophysique, Hopital Jean Bernard, Poitiers, France.

This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantification step. Analytical performances were excellent: within- and between-run CVs of less than 10% in the working range, no significant effect of hemolysis, bilirubin, or lipemia, and no significant interaction between the conjugate and the thyroxin-binding proteins. Magic Lite results (y) correlated well with those obtained by the Sclavo (x) two-step radioimmunoassay (Sclavo, Siena, Italy): y = 1.35x + 1.32 (r = 0.94, n = 267, P less than 0.001, Sxy = 6.29). Clinical sensitivities (diagnostic efficiencies) for hypothyroidism and hyperthyroidism were 0.91 and 0.98 for normal interval limits of 12 and 21.5 pmol/L (95% confidence interval). Magic Lite results in situations where patient therapy, treatment, or unusual conditions can result in a lack of correlation between the clinical status and the FT4 values were qualitatively the same as those obtained by the Sclavo assay.