Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 227-234, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baruthio, F.
Right arrow Articles by Zawislak, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baruthio, F.
Right arrow Articles by Zawislak, R.

Clinical Chemistry, Vol 34, 227-234, Copyright © 1988 by American Association for Clinical Chemistry

Determination of manganese in biological materials by electrothermal atomic absorption spectrometry: a review

F Baruthio, O Guillard, J Arnaud, F Pierre and R Zawislak
INRS, Service Epidemiologie, Vandoeuvre, France.

The great diversity of methods for measuring manganese in biological materials (serum, plasma, whole blood, urine, spinal fluid, and hair) reflects the difficulty in measuring extremely small quantities of this element. Detailed examination of these methods demonstrates that the one most used is flameless atomic absorption spectrometry. In this review we report the different instrument settings for wavelength, slit width, protection gases, graphite furnaces, type of background correction, amounts measured, and thermal programs. We give detailed recommendations by various authors for collecting samples. A thorough description of the preliminary steps and the handling of the specimen samples is also included: direct determination with or without dilution, addition of a matrix modifier or determination after ashing, with or without chelation-extraction steps. The preparation of the standards, procedures used, analytical criteria (accuracy, precision, specificity, detection limit, linearity), problems (interferences, matrix effects), and reference values and their physiological variations are also described. We give a consensus of recommendations concerning the choice of a method.


The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Clin. Nutr.Home page
J. W Finley
Manganese absorption and retention by young women is associated with serum ferritin concentration
Am. J. Clinical Nutrition, July 1, 1999; 70(1): 37 - 43.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
K. Suehiro, J. Gailit, and E. F. Plow
Fibrinogen Is a Ligand for Integrin alpha 5beta 1 on Endothelial Cells
J. Biol. Chem., February 21, 1997; 272(8): 5360 - 5366.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
K. Suehiro, J. W. Smith, and E. F. Plow
The Ligand Recognition Specificity of beta(3) Integrins
J. Biol. Chem., April 26, 1996; 271(17): 10365 - 10371.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.