Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 691-695, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thonnart, B.
Right arrow Articles by Bok, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thonnart, B.
Right arrow Articles by Bok, B.

Clinical Chemistry, Vol 34, 691-695, Copyright © 1988 by American Association for Clinical Chemistry

Ten highly sensitive thyrotropin assays compared by receiver-operating characteristic curves analysis: results of a prospective multicenter study

B Thonnart, O Messian, NC Linhart and B Bok
Hospital Beaujon, Department of Nuclear Medicine, Clichy, France.

We report a prospective multicenter study, undertaken to compare the efficacy of 10 highly sensitive thyrotropin assay kits for the diagnosis of hyperthyroidism. Performances of the kits were compared with a reference diagnosis based on clinical examination, pertinent biological tests, and determination by an independent laboratory of the concentrations in serum of free triiodothyronine and free thyroxin. No thyrotropin determination was used in establishing this reference diagnosis. Receiver-operating characteristic curves were obtained for results from 600 patients (217 hyperthyroid and 383 euthyroid) by each kit. Even though analyses were performed out of the working range of most kits, the clinical correlation was nevertheless excellent. The best results corresponded to a sensitivity of 97.5% associated with a specificity of 96.1% and were significantly better than those obtained with all other kits. Results of this comparison depended greatly on the heterogeneity of the "normal"/"abnormal" categories. When only diffuse hyperthyroidism was considered, sensitivity and specificity were improved for all kits, and there was no significant difference among the five best kits.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.