Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 1474-1478, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gorus, F.
Right arrow Articles by Laureys, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gorus, F.
Right arrow Articles by Laureys, M.

Clinical Chemistry, Vol 34, 1474-1478, Copyright © 1988 by American Association for Clinical Chemistry

A sensitive bioluminescent immunoinhibition test for CK-B subunit activity and a CK-MB specific ELISA compared: correlation with agarose electrophoresis and influence of CK-isoenzyme profile on results

F Gorus, V Claessens, P Goubert and M Laureys
Clinical Chemistry Laboratory, Academic Hospital, Vrije Universiteit Brussel, Belgium.

Searching for alternatives to the imprecise spectrophotometric tests for low-concentration creatine kinase (EC 2.7.3.2) isoenzyme MB (CK- MB), we investigated the analytical performance of two potentially superior approaches--a bioluminescent immunoinhibition assay (I, LKB- Wallac) and an ELISA (enzyme-labeled immunosorbent assay) technique (II, Hybritech)--in comparison with an electrophoretic method (III, Beckman). Only I showed good between-day precision (CV 8.3%) at the upper reference limit, allowing reproducible assay of CK-B subunit activity down to at least 3 U/L. In conditions where CK isoenzyme assays remained unaffected by CK-MM concentrations, test results were proportional to the amount of CK-MB in the sample up to at least 50 U/L for I, 120 micrograms/L for II, and 100 U/L for III (r greater than 0.998 by linear regression analysis). For CK-MB-positive samples, the data by I correlated more closely with values by III (n = 24; r = 0.994) than did results by II (n = 15; r = 0.909), but both methods were equally effective in discriminating between samples with or without electrophoretically supranormal CK-MB activity (93% sensitivity). II was entirely CK-MB specific, whereas CK-B activity by I was consistently (18/18) increased in CK-MB-negative samples containing CK-BB (n = 6; r = 0.996) or macro CK, types 1 or 2 (n = 12; r = 0.930). I is highly sensitive for screening for increased non-MM CK activity, the nature of which should be subsequently clarified by electrophoresis.