Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 1478-1480, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marchetti, P.
Right arrow Articles by Navales, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marchetti, P.
Right arrow Articles by Navales, R.

Clinical Chemistry, Vol 34, 1478-1480, Copyright © 1988 by American Association for Clinical Chemistry

Salivary immunoreactive insulin: a new entry in clinical chemistry?

P Marchetti, C Grossi, R Giannarelli, A Masoni, R Cristofani, M Giannecchini and R Navales
Cattedra di Malattie del Ricambio, Istituto di Clinica Medica II, Pisa, Italy.

The distribution of salivary immunoreactive insulin (S-IRI) and its relation to plasma insulin (P-IRI) and other clinical and metabolic variables were investigated in 93 nondiabetic subjects (60 males, 33 females, ages 11-70 y). S-IRI was measured by RIA, with monoiodinated insulin as labeled antigen and with standards consisting of serial dilutions in saliva of known amounts of native insulin. The sensitivity of the method was 12.1 pmol/L. The intra- and between-assay CVs were near 10%, and analytical recovery exceeded 93% for various insulin concentrations added to saliva. S-IRI, measured after overnight fast, showed a nonguassian distribution in males (skewness 1.18, kurtosis 1.41) and females (skewness 1.71, kurtosis 1.18); mean and median values were higher in males (14.3 and 12.1 nmol/min) than in females (12.1 and 7.15 nmol/min), but not significantly so. S-IRI was significantly correlated with P-IRI both in males (r = 0.75, P less than 0.0001) and females (r = 0.72, P less than 0.0001). These results, particularly the correlation between S-IRI and P-IRI, indicate the possibility of using S-IRI measurement in clinical practice.


The following articles in journals at HighWire Press have cited this article:


Home page
Crit. Rev. Oral Biol. Med.Home page
E. Kaufman and I. B. Lamster
THE DIAGNOSTIC APPLICATIONS OF SALIVA-- A REVIEW
Crit. Rev. Oral. Biol. Med., March 1, 2002; 13(2): 197 - 212.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.