Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 34: 1607-1610, 1988;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bolhuis, P. A.
Right arrow Articles by van der Helm, H. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bolhuis, P. A.
Right arrow Articles by van der Helm, H. J.

Clinical Chemistry, Vol 34, 1607-1610, Copyright © 1988 by American Association for Clinical Chemistry

Rapid determination of the hypoxanthine increase in ischemic exercise tests

PA Bolhuis, R Zwart, PR Bar, M de Visser and HJ van der Helm
Department of Neurology, Academic Medical Centre, Amsterdam, The Netherlands.

After ischemic exercise tests, performed to detect glycogenoses or myoadenylate deaminase (EC 3.5.4.6) deficiency, the increases in serum lactate and ammonia usually are measured. Determination of hypoxanthine instead of ammonia can also be used to show myoadenylate deaminase deficiency, but HPLC of hypoxanthine is time-consuming. As a substitute, we developed an indirect enzymatic equilibrium method for hypoxanthine based on coupling the chromogenic system 3,5-dichloro-2- hydroxy-benzenesulfonic acid/4-aminophenazone with formation of hydrogen peroxide by xanthine oxidase (EC 1.1.3.22). The pH optimum is at 7.8 and the absorbance maximum at 510 nm. The calibration curve is linear from 0 to 100 mumol/L and the detection limit is 0.9 mumol/L. Analytical variability (CV) was 1.5% to 3.6% within-run, 4.5% to 8.5% between-run. The assay can be performed with a standard spectrophotometer or a centrifugal analyzer. The coefficient of correlation was 0.68 between hypoxanthine and ammonia increases in plasma from controls who performed the exercise test.


The following articles in journals at HighWire Press have cited this article:


Home page
ANGIOLOGYHome page
D. Duprez, M. De Buyzere, A. Van Wassenhove, and D. Clement
Evaluation of the Metabolic Compensation After Treadmill Test in Patients with Peripheral Occlusive Arterial Disease
Angiology, February 1, 1992; 43(2): 126 - 133.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Association for Clinical Chemistry.