Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 215-222, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bohler, U.
Right arrow Articles by Schmidt-Gayk, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bohler, U.
Right arrow Articles by Schmidt-Gayk, H.

Clinical Chemistry, Vol 35, 215-222, Copyright © 1989 by American Association for Clinical Chemistry

Two-site immunochemiluminometric assay of intact human parathyrin in serum with use of a tracer peptide purified by reversed-phase high- performance liquid chromatography

U Bohler, E Blind, G Vogel, W Hitzler, D Flentje and H Schmidt-Gayk
Klinisches Laboratorium, Abteilung 2.1.1, Chirurgische Universitatsklinik. Heidelberg, F.R.G.

For this two-site immunochemiluminometric assay of intact human parathyrin (hPTH), the luminescent tracer was synthetic hPTH(53-84), conjugated via succinimide linkage to (aminobutyl)ethyl-isoluminol hemisuccinimide (abei-h). Purification of the labeled hPTH(53-84) by reversed-phase high-performance liquid chromatography allowed isolation of the conjugate having the highest incorporation of abei-h, 1.6 mol per mole of hPTH(53-84). The solid-phase antibody directed against the N-terminal part of hPTH was immobilized by adsorption onto the polystyrene surface of the assay tube and extracted the intact hPTH and N-terminal fragments. Another antibody against synthetic hPTH(53-84), which bound to the C-terminal part of intact hPTH, was indirectly labeled at its second free binding site with the abei-h-labeled hPTH(53- 84). The assay has a detection limit of 0.5 pmol/L; it is accurate, precise, and reliable; and it shows a linear response for samples containing up to 100 pmol of hPTH per liter. The normal reference interval ranged from 1.8 to 5.9 pmol/L; 56 patients with primary hyperparathyroidism had concentrations ranging from 5.9 to 113 pmol/L. The concentrations detected in patients with idiopathic hypoparathyroidism were below the normal reference interval.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Association for Clinical Chemistry.