|
|
||||||||
Clinical Chemistry, Vol 35, 271-274, Copyright © 1989 by American Association for Clinical Chemistry
LH Bernstein, CJ Leukhardt-Fairfield, W Pleban and R Rudolph
Department of Pathology, Bridgeport Hospital, CT 06110.
In this ongoing study, albumin and prealbumin (transthyretin) changes were compared in 40 patients managed with enteral and (or) parental support with attainment of caloric/protein goals. The concentration of prealbumin in serum changed rapidly and more accurately reflected current nutritional status of these patients than did that of albumin. We determined concentrations of albumin and prealbumin that reflected significant improvement in nutritional status, using Rudolph's approach based on Shannon information measures. Reference values for albumin and prealbumin in the treatment populations were 25 g/L and 107 mg/L, respectively. A prealbumin concentration of 135 mg/L or greater reflected a return to stable status.
The following articles in journals at HighWire Press have cited this article:
![]() |
G. Devoto, F. Gallo, C. Marchello, O. Racchi, R. Garbarini, S. Bonassi, G. Albalustri, and E. Haupt Prealbumin Serum Concentrations as a Useful Tool in the Assessment of Malnutrition in Hospitalized Patients Clin. Chem., December 1, 2006; 52(12): 2281 - 2285. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. L. Abu-Rumman, D. G. Armstrong, and B. P. Nixon Use of Clinical Laboratory Parameters to Evaluate Wound Healing Potential in Diabetes Mellitus J Am Podiatr Med Assoc, January 1, 2002; 92(1): 38 - 47. [Abstract] [Full Text] [PDF] |
||||
![]() |
S A McMillan, W Dickey, J P Douglas, and D F Hughes Transthyretin values correlate with mucosal recovery in patients with coeliac disease taking a gluten free diet J. Clin. Pathol., October 1, 2001; 54(10): 783 - 786. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A. Kaysen Malnutrition and the acute-phase reaction in dialysis patients--how to measure and how to distinguish Nephrol. Dial. Transplant., October 1, 2000; 15(10): 1521 - 1524. [Full Text] [PDF] |
||||
![]() |
P. Holownia, D. J. Newman, H. Thakkar, W. D. Bedzyk, H. Crane, Y. Olabiran, C. L. Davey, and C. P. Price Development and validation of an automated latex-enhanced immunoassay for prealbumin Clin. Chem., June 1, 1998; 44(6): 1316 - 1324. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. H. Bernstein What Constitutes a Laboratory Quality Monitoring Program? American Journal of Medical Quality, August 1, 1990; 5(3): 95 - 99. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |