Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 347-354, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lott, J. A.
Right arrow Articles by Kyler, M. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lott, J. A.
Right arrow Articles by Kyler, M. K.

Clinical Chemistry, Vol 35, 347-354, Copyright © 1989 by American Association for Clinical Chemistry

Proficiency testing in a medical-needs context

JA Lott, NR Manning and MK Kyler
Department of Pathology, Ohio State University, Columbus 43210.

Proficiency testing by State and Federal agencies is an ongoing activity of clinical laboratories and an occasional source of anxiety; strict statistical evaluations of "snapshot" laboratory values are inappropriate and medical-needs criteria should be used. The quality of laboratory results largely depends on available technology. Fortunately, for most of the common clinical chemistry analytes there has been a steady reduction of imprecision during the past 20 years. Proficiency testing may have been the stimulus for this improved performance. Medical-needs criteria differ, depending on the testing goal. For proficiency testing, population screening criteria are appropriate, e.g., the College of American Pathologists fixed criteria for the common tests. Stricter criteria are needed for short-term (inpatient) and long-term (outpatient) monitoring of laboratory data. Explicit proficiency-testing limits are given here for nine of the common clinical chemistry tests for each of the three medical-needs criteria described above. The limits consider total error--i.e., bias from the believed correct value, and imprecision. Rather broad limits are acceptable for the commonly performed enzyme tests when used for screening purposes.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Association for Clinical Chemistry.