Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 555-559, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barnard, G.
Right arrow Articles by Lovgren, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barnard, G.
Right arrow Articles by Lovgren, T.

Clinical Chemistry, Vol 35, 555-559, Copyright © 1989 by American Association for Clinical Chemistry

Measurement of estrone-3-glucuronide in urine by rapid, homogeneous time-resolved fluoroimmunoassay

G Barnard, F Kohen, H Mikola and T Lovgren
Department of Hormone Research, Weizmann Institute of Science, Rehovot, Israel.

We describe a liquid-phase nonseparation time-resolved fluorescence immunoassay for measuring estrone-3-glucuronide in undiluted urine. The sensitivity, specificity, and accuracy are similar to those for a conventional separation fluoroimmunoassay or radioimmunoassay, but the speed, convenience, precision, reliability, and clinical utility of the new method are more advantageous. The labeled antigen, a fluorescent europium chelate covalently linked to estrone-3-glucuronide, is incubated for 10 min with a limited concentration of polyclonal or monoclonal antibodies to estrone-3-glucuronyl-6-bovine serum albumin and 10 microL of standard or sample (undiluted urine) in microtiter wells. The fluorescence emanating from the antibody-free label, which is proportional to the concentration of estrone-3-glucuronide in the standard or sample, is then measured in a time-resolved fluorometer. The method is useful for monitoring ovarian function in women.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
K. A. O'Connor, E. Brindle, D. J. Holman, N. A. Klein, M. R. Soules, K. L. Campbell, F. Kohen, C. J. Munro, J. B. Shofer, B. L. Lasley, et al.
Urinary Estrone Conjugate and Pregnanediol 3-Glucuronide Enzyme Immunoassays for Population Research
Clin. Chem., July 1, 2003; 49(7): 1139 - 1148.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Blomberg, P. Hurskainen, and I. Hemmila
Terbium and Rhodamine as Labels in a Homogeneous Time-resolved Fluorometric Energy Transfer Assay of the ß Subunit of Human Chorionic Gonadotropin in Serum
Clin. Chem., June 1, 1999; 45(6): 855 - 861.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. Barnard and F. Kohen
Monitoring ovarian function by the simultaneous time-resolved fluorescence immunoassay of two urinary steroid metabolites
Clin. Chem., July 1, 1998; 44(7): 1520 - 1528.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Association for Clinical Chemistry.