Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 641-644, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fulton, A.
Right arrow Articles by Coleman, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fulton, A.
Right arrow Articles by Coleman, G.

Clinical Chemistry, Vol 35, 641-644, Copyright © 1989 by American Association for Clinical Chemistry

Effect of salivary proteins on binding curves of three radioimmunoassay kits: Amerlex-M progesterone, Amerlex cortisol, and Biodata testosterone

A Fulton, S Chan and G Coleman
Department of Applied Chemistry, Phillip Institute of Technology, Bundoora, Victoria, Australia.

Radioimmunoassay (RIA) is generally used to measure certain salivary hormones because of its high sensitivity. For speed and simplicity, it has been used in the form of "direct" assays, i.e., without first extracting the analyte from its matrix. Investigating the effect of the principal salivary proteins on the binding behavior of three commercial RIA kits, we found that the Amerlex-M [125I]progesterone binding was greatly reduced when alpha-amylase and mucins were added to the binding medium, whereas IgA and IgG were less effective. The Serono Biodata [125I]testosterone binding was unaffected by proteins, while the Amerlex [125I]cortisol binding was decreased by alpha-amylase and mucins. The protein influence was largely eliminated when an extraction step was incorporated. Thus, direct RIA of saliva may be subject to matrix effects, to extents that vary with the kit and that may adversely affect the quality of the assay results.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Clin. Pathol.Home page
C Williams, T Giannopoulos, and E A Sherriff
Best Practice No 170: Investigation of infertility with the emphasis on laboratory testing and with reference to radiological imaging
J. Clin. Pathol., April 1, 2003; 56(4): 261 - 267.
[Abstract] [Full Text] [PDF]