Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 817-820, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berry, M. N.
Right arrow Articles by Peake, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berry, M. N.
Right arrow Articles by Peake, M. J.

Clinical Chemistry, Vol 35, 817-820, Copyright © 1989 by American Association for Clinical Chemistry

Enzymatic determination of potassium in serum

MN Berry, RD Mazzachi, M Pejakovic and MJ Peake
Department of Biochemistry and Chemical Pathology, Flinders University of South Australia, Bedford Park, Australia.

This is a kinetic assay for measuring K+ in serum, based on the activation of pyruvate kinase (EC 2.7.1.40) by K+. We eliminated interference from Na+ and NH4+ ions, which also activate this enzyme, by including Na+-binding and NH4+-consuming reagents in the reaction mixture. The assay was developed with and evaluated in the Cobas Fara centrifugal analyzer (and has been used in other kinetic analyzers). Within-run and between-run CVs were less than 1.4% and less than 1.6%, respectively. The reaction rate per millimole of K+ per liter (0.05 delta A/min) was more than double that of the reagent blank (0.02 delta A/min). Results correlated well with those by flame photometry, and interference from bilirubin, hemoglobin, lipids, heparin, and other cations was negligible. This method, in conjunction with a previous method we have reported in which beta-galactosidase is used for measuring Na+ in serum, offers a practical alternative to the use of ion-selective electrodes and flame photometry for measuring these clinically important monovalent cations in high-throughput or "stat" biochemical analyzers.