Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 1492-1496, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ioannou, P. C.
Right arrow Articles by Konstantianos, D. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ioannou, P. C.
Right arrow Articles by Konstantianos, D. G.

Clinical Chemistry, Vol 35, 1492-1496, Copyright © 1989 by American Association for Clinical Chemistry

Fluorometric determination of magnesium in serum with 2-hydroxy-1- naphthaldehyde salicyloylhydrazone

PC Ioannou and DG Konstantianos
Chemistry Department, University of Athens, Greece.

This simple, rapid, sensitive fluorometric method for determining magnesium is based on formation of a fluorescent complex of magnesium with 2-hydroxy-1-naphthaldehyde salicyloyl-hydrazone in alkaline ethanolic medium (lambda ex = 420 nm, lambda em = 460 nm). The detection limit of the method is 0.05 microgram/L (2 nmol/L) and the relative standard deviations (CVs) are 0.8%, 1.1%, and 2.5% at magnesium concentrations of 50, 5.0, and 0.50 microgram/L, respectively. The standard curve is linear from 0 to 250 micrograms/L (0-10 mumol/L). We investigated the chemistry of the reaction, and have applied the method to determine magnesium in 100-fold-diluted, otherwise untreated serum samples. Within-run CVs for the method were 1.7%, 1.1%, and 1.3% at mean magnesium concentrations of 15.7, 26.4, and 36.2 mg/L, respectively. Day-to-day CVs were 2.7%, and 3.6% at mean magnesium concentrations of 10.1 and 25.5 mg/L, respectively. Samples from 96 hospitalized patients in intensive-care units were analyzed by the proposed method (y) and by an automated colorimetric method involving Magon sulfonate reagent (x). Linear regression analysis of the results yielded: y = 1.01x - 0.04 (r = 0.982, Sxy = 0.90).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Association for Clinical Chemistry.