Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 1726-1730, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McBride, J. H.
Right arrow Articles by Reyes, A. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McBride, J. H.
Right arrow Articles by Reyes, A. F.

Clinical Chemistry, Vol 35, 1726-1730, Copyright © 1989 by American Association for Clinical Chemistry

Measurement of cyclosporine in plasma from patients with various transplants: HPLC radioimmunoassay with a specific monoclonal antibody compared

JH McBride, DO Rodgerson, SS Park and AF Reyes
Department of Pathology, U.C.L.A. School of Medicine 90024-1732.

This study compares cyclosporin A (CsA) concentrations in plasma from patients receiving various transplants, as measured by HPLC and RIA with a monoclonal antibody for CsA and an 125I-labeled ligand. The RIA was restandardized with in-house standards because it overestimated CsA by an average of 23%. The RIA was sensitive to 2 micrograms/L, the standard curve was linear from 20 to 500 micrograms of CsA per liter, analytical recovery was 98%, and CVs were less than 8% for intra- and interassay precision. RIA (y) vs HPLC (x) for 283 plasma samples from 145 patients gave a slope = 1.1256, r = 0.979. When the results were segregated according to transplant type, CsA in liver and heart recipients was overestimated by RIA as compared with HPLC: slope = 1.202, r = 0.973 and slope = 1.1477, r = 0.983, respectively. Adult and pediatric CsA values were acceptable when RIA and HPLC were compared: slope = 1.0755, r = 0.977 and slope = 1.0563, r = 0.980, respectively. For six samples (four heart, two liver recipients) where HPLC and RIA values demonstrated wide discrepancies, repeat HPLC and analysis of eluate fractions gave CsA concentrations nearer values by the initial HPLC assay. We conclude that this RIA cannot be substituted for HPLC in the case of heart and liver recipients. The need for each laboratory to standardize the RIA is obvious.


The following articles in journals at HighWire Press have cited this article:


Home page
J Clin PharmacolHome page
M. Rheeders, M. Bouwer, and T. C. Goosen
Drug-drug interaction after single oral doses of the furanocoumarin methoxsalen and cyclosporine.
J. Clin. Pharmacol., July 1, 2006; 46(7): 768 - 775.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. M. Juenke, P. I. Brown, F. M. Urry, and G. A. McMillin
Specimen Dilution for C2 Monitoring with the Abbott TDxFLx Cyclosporine Monoclonal Whole Blood Assay
Clin. Chem., August 1, 2004; 50(8): 1430 - 1433.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the American Association for Clinical Chemistry.