Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 35: 1874-1877, 1989;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Donohue, J.
Right arrow Articles by Defreese, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Donohue, J.
Right arrow Articles by Defreese, J.

Clinical Chemistry, Vol 35, 1874-1877, Copyright © 1989 by American Association for Clinical Chemistry

Enzyme immunoassay system for panel testing

J Donohue, M Bailey, R Gray, J Holen, TM Huang, J Keevan, C Mattimiro, C Putterman, A Stalder and J Defreese
Diagnostic Division, Abbott Laboratories, Abbott Park, IL 60064.

An immunoassay system based on enzyme immunoassay technology has been developed for quantitative panel testing. The system includes test card disposables, reagents, and an instrument. Patients' samples are processed semiautomatically in the instrument with minimum user intervention. The test card has multiple test areas at individual locations on a membrane solid phase so that simultaneous determinations from a single specimen are possible. Each panel also includes positive and negative reagent procedural controls. Factory-determined calibration curves for each analyte are provided in barcode form with each test kit. The reagents include a specimen dilution buffer, enzyme conjugate, and precipitogenic substrate. Up to 10 test cards at a time can be processed in random-access and continuous-access modes, with automated agitation of sample and reagents over the solid phase, temperature-controlled incubation, and membrane washing and reading, data reduction, and printout of results. The optical reader measures diffuse reflectance and features source intensity and wavelength compensation.


The following articles in journals at HighWire Press have cited this article:


Home page
LupusHome page
S. Binder
Autoantibody Detection Using Multiplex Technologies
Lupus, July 1, 2006; 15(7): 412 - 421.
[Abstract] [PDF]