Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 131-135, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Morris, H. C.
Right arrow Articles by Price, C. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morris, H. C.
Right arrow Articles by Price, C. P.

Clinical Chemistry, Vol 36, 131-135, Copyright © 1990 by American Association for Clinical Chemistry

Development and validation of an automated, enzyme-mediated colorimetric assay of salicylate in serum

HC Morris, PD Overton, JR Ramsay, RS Campbell, PM Hammond, T Atkinson and CP Price
Department of Chemical Pathology, London Hospital Medical College, U.K.

This salicylate-specific assay can be adapted for use with most discrete analyzers, for rapid emergency or routine testing with small serum or plasma sample volumes and a single calibration. The basis of this method is as follows: salicylate monooxygenase (EC 1.14.13.1) converts salicylate to catechol in the presence of NADH; the catechol then reacts with 4-aminophenazone under alkaline conditions, catalyzed by manganese ions, to produce a red dye. Incorporation of an NADH- regenerating system, involving glucose and glucose dehydrogenase, into the enzyme reagent ensures that the working reagent is stable for more than two weeks. The standard curve is linear over the drug concentration range 0 to 5 mmol/L. The CV was less than 4% over 20 days. Results correlated well with those by the Trinder colorimetric method and an HPLC method. We saw no interference by any of 80 drugs we tested at therapeutic concentrations or by endogenous compounds in serum.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
D. R. Dufour, J. A. Lott, F. S. Nolte, D. R. Gretch, R. S. Koff, and L. B. Seeff
Diagnosis and Monitoring of Hepatic Injury. I. Performance Characteristics of Laboratory Tests
Clin. Chem., December 1, 2000; 46(12): 2027 - 2049.