Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 136-139, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schleicher, E. D.
Right arrow Articles by Vogt, B. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schleicher, E. D.
Right arrow Articles by Vogt, B. W.

Clinical Chemistry, Vol 36, 136-139, Copyright © 1990 by American Association for Clinical Chemistry

Standardization of serum fructosamine assays

ED Schleicher and BW Vogt
Diabetes Research Group, Institute for Clinical Chemistry, Munich, F.R.G.

We have calibrated a secondary serum protein standard by use (as primary standards) of samples of albumin and polylysine glycated with [14C]glucose in vitro, the glycation of which was assessed by radioactivity measurements and by elementary analysis for C and N. Using this standard for calibration in our improved fructosamine assay, one obtains an average fructosamine value of 247 mumol/L for nondiabetic individuals (or, in terms of total serum protein, 3.2 mumol/g)--about a tenth the value we obtained when we used the fructosamine assay of Johnson et al. (Clin Chim Acta 1983;127:87-95), standardized with desoxymorpholinofructose. In contrast, results corresponded well with the value for mean glycation of serum proteins, 3 mumol/g, determined by a furosine/HPLC method. Evidently the proposed procedure, in which a standard sharing the binding characteristics of endogenous glycated proteins is used together with our modified new fructosamine assay, leads to more realistic values for the concentrations of glycated serum proteins.


The following articles in journals at HighWire Press have cited this article:


Home page
Cancer Epidemiol. Biomarkers Prev.Home page
M. Platek, V. Krogh, A. Micheli, R. Browne, E. Meneghini, S. Sieri, H. J. Schunemann, V. Pala, M. Barba, G. E. Wilding, et al.
Serum Fructosamine and Subsequent Breast Cancer Risk: A Nested Case-Control Study in the ORDET Prospective Cohort Study
Cancer Epidemiol. Biomarkers Prev., January 1, 2005; 14(1): 271 - 274.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. E. Goldstein, R. R. Little, R. A. Lorenz, J. I. Malone, D. Nathan, C. M. Peterson, and D. B. Sacks
Tests of Glycemia in Diabetes
Diabetes Care, July 1, 2004; 27(7): 1761 - 1773.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.