Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 81-87, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jabs, C. M.
Right arrow Articles by Thomas, E. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jabs, C. M.
Right arrow Articles by Thomas, E. J.

Clinical Chemistry, Vol 36, 81-87, Copyright © 1990 by American Association for Clinical Chemistry

Adenosine, inosine, and hypoxanthine/xanthine measured in tissue and plasma by a luminescence method

CM Jabs, P Neglen, B Eklof and EJ Thomas
Department of Surgery, Faculty of Medicine, Kuwait University, Safat.

This simple method for sequentially quantifying hypoxanthine (HYP), inosine (INO), and adenosine (ADN) concentrations exploits the H2O2 peroxidase-catalyzed chemiluminescence of luminol. Though applied here only to tissue and plasma, this method can be adapted to analyze other body fluids. HYP in human plasma was stable for 30 min in 10 mmol/L EDTA reagent, whereas ADN was slowly converted to INO. Analytical recovery of HYP and INO added to plasma was 102% each; that of ADN was 95%. The within-run mean CVs for determinations of HYP, INO, and ADN at 1 mumol/L were 3.46%, 2.65%, and 3.01%; at 10 mumol/L they were 2.16%, 1.88%, and 1.63%, respectively. Corresponding between-run CVs were 5.34%, 4.09%, and 4.17%; and 3.43%, 2.40%, and 2.88%, respectively. Bilirubin at a concentration greater than 50 mumol/L interferes, but this interference is eliminated by bilirubin oxidase. Results for both tissue and plasma are compared with previously published results based on different analytical methods.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Biol. Chem.Home page
M. Vodnala, A. Fijolek, R. Rofougaran, M. Mosimann, P. Maser, and A. Hofer
Adenosine Kinase Mediates High Affinity Adenosine Salvage in Trypanosoma brucei
J. Biol. Chem., February 29, 2008; 283(9): 5380 - 5388.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.