Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 2109-2113, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Siekmeier, R.
Right arrow Articles by Gross, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siekmeier, R.
Right arrow Articles by Gross, W.

Clinical Chemistry, Vol 36, 2109-2113, Copyright © 1990 by American Association for Clinical Chemistry

Insufficient accuracy and specificity of polyanion precipitation methods for quantifying low-density lipoproteins

R Siekmeier, W Marz and W Gross
Custav Embden-Zentrum der biologischen Chemie, J.W. Goethe-Universitat, Frankfurt/Main, F.R.G.

Recently, polyanion precipitation assays for low-density lipoprotein (LDL)-cholesterol have been found to underestimate their analyte in normolipidemic samples (Siekmeier et al., Clin Chim Acta 1988;177:221- 30). Therefore, accuracy, specificity, and interference by nonesterified fatty acids have been studied for three precipitants (obtained by heparin, dextran sulfate, or polyvinyl sulfate precipitation). At normal concentrations of LDL, precipitation is incomplete, whereas it is nearly quantitative at high concentrations of LDL. The polyvinyl sulfate reagent markedly responds to variations in the amount of non-LDL protein present in the precipitation mixture. In the dextran sulfate and the polyvinyl sulfate method, but not in the heparin method, the percentages of LDL precipitated notably increase as the concentration of the polyanion compound is decreased. In either assay, very-low-density lipoproteins, but not high-density lipoproteins, are significantly coprecipitated (dextran sulfate 28%, polyvinyl sulfate and heparin 66%) in a concentration-independent fashion. Increased concentrations of nonesterified fatty acids markedly interfere with the dextran sulfate and polyvinyl sulfate assay, but do not much affect results with the heparin reagent.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. Nauck, G. R. Warnick, and N. Rifai
Methods for Measurement of LDL-Cholesterol: A Critical Assessment of Direct Measurement by Homogeneous Assays versus Calculation
Clin. Chem., February 1, 2002; 48(2): 236 - 254.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Nauck, W. Marz, and H. Wieland
New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol
Clin. Chem., July 1, 1998; 44(7): 1443 - 1451.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.