Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 230-233, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Koch, D. D.
Right arrow Articles by Westgard, J. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Koch, D. D.
Right arrow Articles by Westgard, J. O.

Clinical Chemistry, Vol 36, 230-233, Copyright © 1990 by American Association for Clinical Chemistry

Selection of medically useful quality-control procedures for individual tests done in a multitest analytical system

DD Koch, JJ Oryall, EF Quam, DH Feldbruegge, DE Dowd, PL Barry and JO Westgard
Department of Pathology and Laboratory Medicine, Medical School, University of Wisconsin, Madison 53792.

Quality-control (QC) procedures (i.e., decision rules used, numbers of control measurements collected per run) have been selected for individual tests of a multitest analyzer, to see that clinical or "medical usefulness" requirements for quality are met. The approach for designing appropriate QC procedures includes the following steps: (a) defining requirements for quality in the form of the "total allowable analytical error" for each test, (b) determining the imprecision of each measurement procedure, (c) calculating the medically important systematic and random errors for each test, and (d) assessing the probabilities for error detection and false rejection for candidate control procedures. In applying this approach to the Hitachi 737 analyzer, a design objective of 90% (or greater) detection of systematic errors was met for most tests (sodium, potassium, glucose, urea nitrogen, creatinine, phosphorus, uric acid, cholesterol, total protein, total bilirubin, gamma-glutamyltransferase, alkaline phosphatase, aspartate aminotransferase, lactate dehydrogenase) by use of 3.5s control limits with two control measurements per run (N). For the remaining tests (albumin, chloride, total CO2, calcium), requirements for QC procedures were more stringent, and 2.5s limits (with N = 2) were selected.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
W. Gernand
How reliable are critical error calculations?
Clin. Chem., May 1, 2006; 52(5): 895 - 896.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Neubauer, C. Wolter, C. Falkner, and D. Neumeier
Optimizing frequency and number of controls for automatic multichannel analyzers
Clin. Chem., May 1, 1998; 44(5): 1014 - 1023.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Chesher and L. Burnett
Equivalence of Critical Error Calculations and Process Capability Index Cpk
Clin. Chem., June 1, 1997; 43(6): 1100 - 1101.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
G. S. Cembrowski
Thoughts on quality-control systems: a laboratorian's perspective
Clin. Chem., May 1, 1997; 43(5): 886 - 892.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. S. Neubauer
The EWMA control chart: properties and comparison with other quality-control procedures by computer simulation
Clin. Chem., April 1, 1997; 43(4): 594 - 601.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. A. Parvin
Quality-control (QC) performance measures and the QC planning process
Clin. Chem., April 1, 1997; 43(4): 602 - 607.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. O. Westgard and B. Stein
Automated Selection of Statistical Quality-Control Procedures to Assure Meeting Clinical or Analytical Quality Requirements
Clin. Chem., February 1, 1997; 43(2): 400 - 403.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.